Hourly climate data for Ontario’s electric sector, from 1950 to 2100

Client
EPRI, with the Climate Risk Institute
Years
2024 to 2025
Services
Extremes
Region
Ontario
A line of high-voltage transmission towers in a misty field at sunrise

1950 to 2100

hourly air temperature for each of 30 Ontario sites

9

drought time scales, 1 to 48 months

2

emissions pathways, SSP1-2.6 and SSP3-7.0

5

variables: temperature, precipitation, drought, freezing rain and streamflow

The question

EPRI’s Ontario case study is building guidance on the costs and benefits of climate adaptation for the electric sector. Power-system models need climate inputs by the hour, not by the month. Which datasets are good enough for Ontario, how do you get hourly projections out of daily climate models, and how do you document it so the results hold up?

What we did

Working with the Climate Risk Institute, Climalogik sourced, harmonized and documented the climate data behind EPRI’s Ontario case study. For each of the 30 requested sites we produced hourly air temperature and precipitation from 1940 to 2024 from the ERA5 reanalysis, and projections from 1950 to 2100 from the NEX-GDDP-CMIP6 ensemble under SSP1-2.6 and SSP3-7.0: daily precipitation, and air temperature disaggregated from daily to hourly with an analog method (Teddy-Tool) that takes its hourly patterns from the reanalysis.

We computed the SPEI drought index at nine time scales from 1 to 48 months, assembled annual freezing rain frequencies and three-hourly freezing rain series for past and future climate from Canadian Regional Climate Model (CRCM5) simulations, alongside observed events from the Canadian Disaster Database and Environment and Climate Change Canada’s severe weather database, and compiled daily streamflow and annual low flows for 903 Ontario hydrometric stations from the Water Survey of Canada. Every dataset came with its licence, its uncertainties and its known limits written down.

  • ERA5
  • NEX-GDDP-CMIP6
  • Hourly disaggregation
  • SPEI
  • CRCM5 freezing rain

What EPRI received

  • Hourly air temperature from 1950 to 2100 for each site under two pathways, hourly precipitation from 1940 to 2024, and daily precipitation projections to 2100
  • SPEI drought index at 1, 3, 6, 9, 12, 18, 24, 36 and 48 months, to 2100
  • Annual freezing rain frequencies and three-hourly freezing rain series for past and future climate, with the observed event record
  • Historical daily streamflow and annual low flows for 903 Ontario hydrometric stations
  • Technical documentation of every source, method, licence and limitation

What changed

EPRI’s Ontario case study has site-specific climate inputs with every source, method, licence and limitation documented, so the adaptation investments it helps prioritize can be traced back to the data and the assumptions behind them.

Hazards covered

  • Extreme heat and cold
  • Extreme rainfall
  • Drought
  • Freezing rain and ice